{"id":41415746879578,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"IMCIS22","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"ABB IMCIS22 Control I\/O Module","public_title":null,"options":["Default Title"],"price":25000,"weight":200,"compare_at_price":54000,"inventory_management":"shopify","barcode":"Sweden","requires_selling_plan":false,"selling_plan_allocations":[]}

Descripción

Overview

The ABB IMCIS22 Control I/O Module is a versatile device designed for industrial automation applications. It provides a combination of digital inputs, digital outputs, and analog inputs, making it suitable for a wide range of control and monitoring tasks. Known for its reliability, accuracy, and flexibility, the IMCIS22 integrates seamlessly into various automation systems.

Technical Specifications

Power Requirements

  • Operating Voltage:
    • +5 VDC (±5%)
    • +15 VDC (-2.5%, +5%)
    • -15 VDC (-5%, +2.5%)
    • +24 VDC (±10%) (supplied via P3 connector from termination unit)
  • Current:
    • +5 V: 100 mA typical, 180 mA maximum
    • +15 V: 27 mA typical, 35 mA maximum
    • -15 V: 23 mA typical, 30 mA maximum
    • +24 V: 46 mA typical, 65 mA maximum
  • Power Dissipation (logic only):
    • +5 V: 0.5 W typical, 0.9 W maximum
    • +15 V: 405 mW typical, 525 mW maximum
    • -15 V: 345 mW typical, 450 mW maximum
    • +24 V: 1.10 W typical, 1.56 W maximum
  • Overvoltage Category (II per IEC 61010-1): I for circuits above 150 V, II for circuits below 150 V

Digital Inputs

  • Number: 3, optically isolated
  • Voltages (±10%): 120 VAC, 24 VDC, 48 VDC, 125 VDC
  • Current (typical): 6 mA, 5.5 mA, 4.7 mA, 4.5 mA
  • Turn-on Voltage (min.): 81 VAC, 19.5 VDC, 26.7 VDC, 90.5 VDC
  • Turn-off Voltage (max.): 45 VAC, 13 VDC, 13 VDC, 55 VDC
  • Maximum Input Current at Minimum Turn-on: 3.8 mA, 4 mA, 2 mA, 2.4 mA
  • Off-leakage Current (max.): 1.6 mA (at Vin ≤45 VAC 60 Hz), 50 nA (at Vin ≤10.5 VDC)
  • DC Response Time: 17 ms (fixed)

Digital Outputs

  • Number: 4, open collector, optically isolated
  • Off Output Voltage VI/O (nominal): 24 ±10% VDC or 48 ±10% VDC
  • On Output Voltage: 1.5 VDC maximum
  • Off Output Current: 10 µA maximum
  • On Output Current: 250 mA maximum at 24 VDC, 125 mA maximum at 48 VDC

Analog Inputs

  • Number: 4
  • Type: 1-5 VDC (differential/single-ended) or 4-20 mA
  • Termination Unit Configured: 1 powered or unpowered current (4-20 mA), Single-ended or differential voltage (1-5 VDC)
  • Input Impedance: >1 MΩ
  • Common Mode Voltage: ±10 VDC
  • Normal Mode Rejection: >76 dB at 50/60 Hz (IMCIS22)
  • Common Mode Rejection: 90 dB from DC to 60 Hz (IMCIS22)
  • Response Time per Channel (100% Step Change): 2.4 sec to 95% of final value (IMCIS22)
  • A/D Resolution: 12 bits for analog inputs

Analog Outputs

  • Number: 2
  • Type: 4-20 mA or 1-5 VDC
  • Output Load - Current Load: 600 Ω/600 mH (maximum)
  • Output Load - Voltage Load: >1 kΩ
  • D/A Resolution: 10 bits for analog outputs
  • Current Limiting: Short circuit protection 50 mA (nominal)
  • Analog Accuracy:
    • Input at 25°C (77°F) Standard Condition:
      • Terminal Based Linearity: ±0.03% of full scale range
      • Repeatability: ±0.03% of full scale range
      • Deadband: ±0.03% of full scale range
      • Accuracy: ±0.1% of full scale range
    • Output at 25°C (77°F) Standard Condition:
      • Terminal Based Linearity: ±0.1% of full scale range
      • Repeatability: ±0.05% of full scale range
      • Accuracy: ±0.15% of full scale range (voltage mode), ±0.25% of full scale range (current mode)
  • Temperature Effect: ±0.002% of full scale range/°C (0° to 70°C)
  • Input Cross Talk Rejection (Channel to Channel): 50 dB (min.) at 25°C (77°F)/-78 dB (typ) at 25°C (77°F)

Mounting

  • Mounting: Occupies one slot in a standard module mounting unit

Environmental

  • Ambient Temperature (per IEC-68-2-1, 2,14): 0° to 70°C (32° to 158°F) (internal cabinet rating)
  • Relative Humidity (per IEC68-2-3): 5% to 95% up to 55°C (131°F), noncondensing, 5% to 45% at 70°C (158°F), noncondensing
  • Pollution Degree: 1
  • Atmospheric Pressure: Sea level to 3 km (1.86 mi)
  • Air Quality (per ISA S71.04, Class LA, LB, LC - Level 1): Noncorrosive

Mostrar más

Aceptamos pedidos al por mayor y tenemos una cantidad mínima de pedido de solo una unidad.

Si lo solicita, podemos proporcionar toda la documentación necesaria, incluidos certificados de origen/conformidad y otros documentos de exportación requeridos.

Para los artículos en stock, nuestro objetivo es realizar la entrega dentro de 1 a 3 días después de la confirmación del pago. Los artículos con plazos de entrega específicos se entregarán de acuerdo con el cronograma cotizado.

Aceptamos pago 100% T/T (Transferencia Telegráfica) antes del envío. Para artículos con plazos de entrega, se requiere un depósito del 30 % por adelantado y el 70 % restante se debe pagar antes del envío. Para transferencias en RMB, contáctenos si tiene un agente en China.

Ofrecemos una garantía estándar de un año en todos los artículos nuevos y originales. Si necesita una garantía extendida, comuníquese con nosotros para obtener detalles de costos adicionales.

Su satisfacción es importante para nosotros. Si necesita devolver un artículo, debe hacerlo dentro de los 30 días posteriores a la fecha del pedido. El producto debe estar sin usar, sin abrir y en su embalaje original con todos los accesorios incluidos. Los reembolsos se procesan dentro de 5 a 7 días hábiles después de recibir el artículo devuelto. Tenga en cuenta que los gastos de envío y relacionados no son reembolsables.

Presentado

Productos complementarios